Chapter 4 – Command Line Interface (CLI)
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A) 60
SNTP Client Commands – Setup
Command Syntax set sntp-client daylight-saving end-weekday <dayofweek>
where
dayofweek = Sunday, Monday … Saturday
Description
Sets the end weekday to use during the Day Light Saving Mode.
Default Value
Sunday
Success
OK
Error 2. Invalid arguments
„error: Invalid end day of the week“
2. Too few arguments
“Usage: set sntp-client daylight-saving end-weekday <dayofweek>
Type set sntp-client daylight-saving end-weekday ? for more
information”
Command Syntax set sntp-client daylight-saving end-month <month>
where
month = january, …december
Description
Sets the end month to use during the Day Light Saving Mode.
Default Value
October
Success
OK
Error 2. Invalid arguments
„error: Invalid end month“
2. Too few arguments
“Usage: set sntp-client daylight-saving end-month <month>
Type set sntp-client daylight-saving end-month ? for more information”
Command Syntax set sntp-client daylight-saving end-time <hh:mm>
where
hh = 00 to 23
mm = 00 to 59
Description
Sets the end time to use during the Day Light Saving Mode.
Default Value
02:00
Success
OK
Error 2. Invalid arguments
„error: Invalid end time“
2. Too few arguments
“Usage: set sntp-client daylight-saving end-time <hh:mm>
Type set sntp-client daylight-saving end-time ? for more information”
SNTP Client Commands – Show
Command Syntax show sntp configuration
Description
Displays the SNTP configuration
Default Value
NA
Success
OK
Error 1. Too few arguments
Possible value(s) are configuration