Multi-tech-systems MT5634ZPW-PCI Uživatelský manuál Strana 46

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 94
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 45
MT5634ZPW-PCI
46
Owners Manual
Command: \N
n
Error Correction Mode Selection
Values:
n
= 0–5, or 7
Default: 3
Description: \N0 Non-error correction mode with data buffering (same
as
&Q6
).
\N1 Direct mode.
\N2 MNP reliable mode.
\N3 V.42/MNP auto-reliable mode.
\N4 V.42 reliable mode.
\N5 V.42, MNP, or non-error correction (same as
\N3
).
\N7 V.42, MNP, or non-error correction (same as
\N3
).
Command: \Q
n
Local Flow Control Selection
Values:
n
= 0, 1, or 3
Default: 3
Description: \Q0 Disable flow control (same as
&K0
).
\Q1 XON/XOFF software flow control (same as
&K4
).
\Q2 CTS-only flow control. Not supported—responds
ERROR.
\Q3 RTS/CTS hardware flow control (same as
&K3
).
Command: \T
n
Inactivity Timer
Values:
n
= 0–255
Default: n/a
Description: \Tn Inactivity timer setting contingent on either \T value or
S-Register S30 value (e.g., AT\T45&W0<cr>
configures in parallel ATS30=45&W0<cr>), and vice
versa.
Command: \V
n
Protocol Result Code
Values:
n
= 0 or 1
Default: 1
Description: \V0 Disable protocol result code appended to DCE speed.
\V1 Enable protocol result code appended to DCE speed.
Command: \X
n
XON/XOFF Pass-Through
Values:
n
= 0 or 1
Defaults: 0
Description: \X0 Respond to and discard XON/XOFF characters.
\X1 Not supported—responds ERROR.
Zobrazit stránku 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 93 94

Komentáře k této Příručce

Žádné komentáře